Model Type |
HR-INV-X01-006 |
HR-INV-X01-010 |
HR-INV-X01-020 |
HR-INV-X01-030 |
Norminal Power Rating (kVA) |
0.6 |
1.0 |
2.0 |
3.0 |
|
|
|
|
|
Input |
|
|
|
|
Recommended Input PV Power (W) |
750 |
1250 |
2500 |
3750 |
Max. DC Input Power (W) |
700 |
1200 |
2350 |
3500 |
Max. Input Voltage (Vdc) |
400 |
400 |
400 |
400 |
Norm. Input Voltage (Vdc) |
280 |
280 |
280 |
280 |
Min. Input DC Voltage (Vdc) |
150 |
150 |
150 |
150 |
MPPT Voltage Range (Vdc) |
150 ~ 400 |
150 ~ 400 |
150 ~ 400 |
150 ~ 400 |
Max. Input DC Current (Adc) |
4.5 |
6 |
6+ 6 |
10+ 10 |
Max. DC Voltage Ripple (Vpp) |
< 10% |
< 10% |
< 10% |
< 10% |
Input Connection |
Plug |
Plug |
Plug |
Plug |
Number of Input Connectors (pair) |
1 |
1 |
2 |
3 |
Number of MPPT Channel |
1 |
1 |
2 |
2 |
Input Transient Voltage Suppression |
Yes |
Yes |
Yes |
Yes |
Earth Fault Detection and Indication |
Yes |
Yes |
Yes |
Yes |
Opposite Polarity Protection |
Yes |
Yes |
Yes |
Yes |
Input Current Limitation |
Yes |
Yes |
Yes |
Yes |
Input Reverse Current Blocking |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
Output |
|
|
|
|
Max. Output AC Power (VA) |
660 |
1100 |
2200 |
3300 |
Norm. Output AC Power (VA) |
600 |
1000 |
2000 |
3000 |
Power Factor |
1.0 by default, customer specify |
1.0 by default, customer specify |
1.0 by default, customer specify |
1.0 by default, customer specify |
Output Current THD |
<4%, comply with IEEE1547 |
<4%, comply with IEEE1547 |
<4%, comply with IEEE1547 |
<4%, comply with IEEE1547 |
Norm. Grid Voltage (Vrms) |
230 |
230 |
230 |
230 |
Grid Voltage Range (Vrms) |
88%~110% of norm grid voltage by |
88%~110% of norm grid voltage by |
88%~110% of norm grid voltage by |
88%~110% of norm grid voltage by |
|
default, adjusted to local regulation |
default,adjusted to local regulation |
default, adjusted to local regulation |
default, adjusted to local regulation |
Max. Output AC Current (Arms) |
2.6 |
4.3 |
8.7 |
13.0 |
Max. Output AC Current (Arms) |
3.0 |
5.0 |
10.0 |
15.0 |
Norm. Grid Frequency (Hz) |
50 |
50 |
50 |
50 |
Grid Frequency Range (Hz) |
49.5 ~ 50.5 by default, |
49.5 ~ 50.5 by default, |
49.5 ~ 50.5 by default, |
49.5 ~ 50.5 by default, |
|
adjusted to local regulation |
adjusted to local regulation |
adjusted to local regulation |
adjusted to local regulation |
Transformer Isolation Between |
Yes |
Yes |
Yes |
Yes |
System and Grid |
|
|
|
|
Grid Connection Wiring |
Terminal block |
Terminal block |
Terminal block |
Terminal block |
Grid disconnection |
Relay |
Relay |
Relay |
Relay |
Output Shrot Circuit Protection |
Yes, Current control |
Yes, Current control |
Yes, Current control |
Yes, Current control |
Output Transient Voltage Suppression |
Yes |
Yes |
Yes |
Yes |
Non-Islanding |
Yes, Comply with UL 1741 |
Yes, Comply with UL 1741 |
Yes, Comply with UL 1741 |
Yes, Comply with UL 1741 |
Electromagnetic Compatibility |
Comply with FCC Rules Part 15, |
Comply with FCC Rules Part 15, |
Comply with FCC Rules Part 15, |
Comply with FCC Rules Part 15, |
|
Class B |
Class B |
Class B |
Class B |
|
|
|
|
|
Power Efficiency (with isolation) |
|
|
|
|
> 50% of Norm. Output Power (%) |
>91.0 |
>91.5 |
>92.5 |
>93.0 |
At 100% of Norm. Output Power (%) |
>93.0 |
>93.5 |
>94.0 |
>94.5 |
|
|
|
|
|
Packaging |
|
|
|
|
Enclosure |
IP65, for indoor and outdoor |
IP65, for indoor and outdoor |
IP65, for indoor and outdoor |
IP65, for indoor and outdoor |
|
installtion |
installtion |
installtion |
installtion |
Weight (kg) |
16 |
22 |
28 |
33 |
Demension (H x W x D, mm) |
312 x 365 x 210 |
312 x 365 x 210 |
365 x 430 x 230 |
365 x 430 x 230 |
|
|
|
|
|
Environment |
|
|
|
|
Operation Ambient Teperature ( ) |
-25 ~ +50 |
-25 ~ +50 |
-25 ~ +50 |
-25 ~ +50 |
Storage Ambient Temperature ( ) |
-40 ~ +70 |
-40 ~ +70 |
-40 ~ +70 |
-40 ~ +70 |
Elevate Above Sea Level (m) |
4000 (Max. Temp +40 ) |
4000 (Max. Temp +40 ) |
4000 (Max. Temp +40 ) |
4000 (Max. Temp +40 ) |
|